Repair projects

allen-bradley-servis-001_800x600

Allen Bradley frequency inverter (11.5 kW) repair

Allen Bradley frequency inverter (11.5 kW) repair
The extent to which the device was damaged was visible only when we performed the initial cleaning of dust and burnt out parts. In addition to various parts being burnt out (input filters, input full wave rectifier and IGBT module), and the visible burning out of the printed conductive tracks at the input part due to the intensity of the voltage, an interesting malfunction was found later on…

accu-charger-servis-promatis

Accu Charger Repair

The device was visibly burnt out. Its main microcontroller and several surrounding elements had a completely black and burnt out casing. The device was under load to charge completely empty batteries.

Emergency Unit JEU 211A

JEU211A fire alarm repair

The JEU211A fire alarm is of extreme importance to the safety of people in the case of a fire in large buildings, and its repair was a real challenge for our company. Before repairing the device, we noticed that the pressing of the alarm button did not activate the alarm light, no voice could be heard …

SEW Eurodrive

SEW Eurodrive 35kW repair

The IGBT module in the device was destroyed because the output lines were not properly connected to the motor (human error). The strange thing was that, despite the quick reaction of the fuse, the output IGBT module had still burnt out…

Servis frekventnog pretvarača za liftove trvtke KONE

Repair of the frequency inverter for elevators KONE.

The lightning striking the installations of the elevator power supply caused the protective parts in the device to burn out, but also destroyed the IGBT module. The interesting aspect of this repair was that, despite high resistance to voltage, the optocouplers that galvanically separate the power circuits from the electronic, control circuits, were damaged…

Lenze EVS 3200 series

Lenze Servo Frequency Converter Service, Series EVS-932X-ES
The device displayed an OC1 error, indicating activation of the output overcurrent protection. In this case, the current transformers on the U and V lines, labelled LA-25NP, need to be replaced.

Fuji Electric Frenic MEGA serija 5.5kW

A series of high-power, compact FRENIC MEGA frequency converters from Fuji Electric Ltd. The device failed the diode test, revealing a fully short-circuited main power IGBT module. Replacing the IGBT module also revealed a damaged TLP421 optocoupler with its external diode, which was replaced with a generic PC817.

Hardware down?  We fix what others can’t.

Fault Detected. Problem Solved. Our repair engineers diagnose and restore even the most complex electronics.